Each flume shall have a distinctive line or marking to indicate the staring zone in which only one rider at a time is permitted. Bathers shall be so routed that the crossing of street shoes and wet barefoot traffic is kept to a minimum. All walls surrounding an indoor residential swimming pool must comply with the above-stated requirements for building walls used as all or part of a barrier around an outdoor residential swimming pool. If mirrors are provided they shall be unbreakable or of safety glass. All outlets shall be covered with suitable protective covers or grates which have been tested and approved by a nationally recognized testing laboratory. 3/20/98 (Effective 2/20/98) – corrected 105 CMR – 1773. for the purpose of computing bather load capacity, those portions of the swimming pool five feet or less in depth shall be designated as “non-swimmer” areas. FAXED SIGNATURES ARE NOT ACCEPTABLE. Diving equipment shall be rigidly constructed and properly anchored with sufficient bracing to insure stability under the heaviest reasonable load. This standard excludes residential units and facilities used or under the direct supervision and control of licensed medical personnel. Residential Swimming Pools was enacted to protect the health and safety of citizens residing near residential swimming pools in 1999. Swimming, wading and special purpose pool water shall be treated in accordance with the following tables: Tests for residual disinfectant shall be made four times daily, once during the peak load by the pool operator, or more often if required by the Board of Health. 3/20/98 (Effective 2/20/98) – corrected 105 CMR – 1775. All permits shall expire no more than 12 months following the date of issue, and may be revoked for cause at any time by the Board of Health (. 3109.3 Public swimming pools. Suitable automatic equipment shall be provided and so installed as to permit adequate disinfection of all the pool water. (M.G.L. Chapter 140, Section 206, of the state’s General Laws calls for a 6-foot tall fence to enclose the pool, and that gates be self-latching with latches four feet from the ground. Stretch Energy Code: 780 CMR Appendix AA Stretch Energy Code; Swimming Pool & Spa Codes. Lifeguard Certificate or an equivalent certification, provided however, that no such alternative certification shall be deemed equivalent unless it shall contain all of the minimum requirements mandated or required by one or more of the foregoing certification programs; and, a current American Red Cross CPR Certificate for the Professional Rescuer or American Heart Association CPR Certificate for the Health Care Provider, or National Safety Council CPR Training; and. The operator of any water slide flume shall be familiar with the provisions of 105 CMR 435.000 and every other applicable law and regulation pertaining to water slide flumes. It does not include any special purpose pool or residential pool as herein defined nor does it include any pool used primarily for baptismal purposes or the healing arts. This system shall be capable of maintaining the water quality standards of 105 CMR 435.28 through 435.31. Plane surfaces tangent to allowable coving may be used in lieu of curves. No person suffering a fever, cough, cold, inflammation of the eyes, nasal or ear discharges, or any communicable disease shall be allowed the use of the pool. Office of the Secretary of the Commonwealth, Regulation Filing To be completed by filing agency. In general, impervious materials and light colors should be used throughout. 20 square feet shall be provided in the swimming area for each swimmer expected at time of maximum load. If at any time the swimming, wading or special purpose pool water does not conform with the requirements set forth in 105 CMR 435.28 through 435.31, the operator shall immediately close the pool until the pool water conforms with those standards. The pool supervisor shall ensure that on-site pool personnel are adequately trained in the safe, sanitary and effective operation of the pool and its equipment. Diving boards shall be of sound construction, free from splinters or dangerous cracks, and shall be capable of supporting the heaviest load under conditions of reasonable use. Wading Pool means a pool of water in a basin having a maximum depth of less than two feet intended chiefly as a wading place for children. Note 3. This rule is designed to prevent swimming pools hazards. Each shall be automatically adjustable to variations in water level over a range of at least three inches. The overflow channel should provide an acceptable hand hold for bathers and should not be less than three inches deep. Drainage from the channels can be returned to the pool water recirculation system ahead of the filters (ordinarily at the balancing tanks or at pump suction), provided that, unless channels are self cleaning, provisions shall be made for diverting the channel water to waste when cleaning the channel or walkway. IBC Section 3109 addresses the specific requirements for swimming pool enclosures and safety devices. The Board of Health may cause samples of swimming, wading, or special purpose pool water for bacteriological analysis to be taken from the pool whenever it considers it necessary. 70 East Main St . Any waste water resulting from draining a swimming, wading or special purpose pool shall be dechlorinated prior to its discharging. 1 0 obj <> endobj 2 0 obj <> endobj 3 0 obj <> endobj 4 0 obj <>/Type /Page>> endobj 5 0 obj <> endobj 6 0 obj <> endobj 7 0 obj <> stream The entries and exits on the sides of the deep area of a pool shall be … 's MA BUILDING CODES ON SWIMMING POOLS SECTION 780 CMR 120 looks good? International Swimming Pool & Spa Code: 2015 ISPSC; M.G.L. It is not required that the pool supervisor be on the premises at all times. Department of Development and Permits 306 Cedar Road, City Hall 2. nd . The building codes of Massachusetts adopt the the International Building Code 2015 (IBC 2015), International Residential Code 2015 (IRC 2015), International Existing Building Code 2015 (IEBC 2015), International Mechanical Code 2015 (IMC 2015), International Energy Conservation Code 2015 (IECC 2015), International Energy Conservation Code 2018 (IECC 2018), International … In addition, all outdoor, inground swimming pools shall be equipped with a rescue hook. Requirements on the plot plan are lot lines, set backs, Swimming Pool, Code Compliant Barrier, proposed addition and decks or porches, accessory structures, lot size, lot coverage, zoning district and completed on the Town of Needham Form. All lifeguards shall direct their attention to all persons in their assigned areas while on duty. Phone: (757) 382-6018 . In addition, there shall be signs which are readily visible stating “CHILDREN UNDER AGE 16 SHOULD NOT USE SWIMMING POOL WITHOUT AN ADULT IN ATTENDANCE” and ADULTS SHOULD NOT SWIM ALONE.”. The water depth of every swimming pool shall be plainly marked on the pool deck at the edge of the pool and on the vertical pools walls, at or above the water surface. The location of the emergency communication device must be in an area that is unlocked and available to both the staff and the public at all times. The finish of the walls and floors of every swimming, special purpose and wading pool shall be of concrete, cement, mortar, tile, paint, vinyl liner, fiberglass or other inert and impervious material, shall be reasonably enduring, shall be moderately smooth and free from cracks, and shall be of light color. The Department may approve innovative equipment and operating procedures if it can be demonstrated by the applicant that their use will achieve the intent of 105 CMR 435.000 to provide a reasonable safe environment and that any hazard to public health is not greater than that of other approved equipment and procedures. Any revision or change in the approved plans and specifications which may affect the capacity or the health or safety features of the swimming, wading or special purpose pool, shall be submitted to the Board of Health for review. The use of oils and body lotion by bathers is prohibited. Note 1: Public and semi-public outdoor in-ground swimming pool enclosures shall conform to the requirements of MGL c.140 § 206. 200-400, If cyanuric acid is used to stabilize the free available residual chlorine, or if one of the chlorinated isocyanurate compounds is used as the disinfecting chemical, the concentration of cyanuric acid in the water should be at least 30 mg/l, but shall not exceed 100 mg/l. This chapter covers all consumer product safety codes, including swimming pool slides (Part 1207). Such an order shall be complied with in accordance with its directions and no person shall be allowed to enter the water of the swimming, wading or special purpose pool, unless and until the permit has been reissued or the order has been revoked in writing by the Board of Health. For males, urinals may be substituted for up to one third of the number of water closets required. Minimum Standards for Swimming Pools, State Sanitary Code, ORIGINAL PUBLICATION REFERENCE: Register Number 837 Date 2/20/98, Multiple corrections to text of regulations previously printed in Massachusetts, AGENCY CONTACT: Howard Wensley PHONE: (617) 983-6761, ADDRESS: 305 South Street, Jamaica Plain, MA. A suitable handrail shall be provided at one side or in the center of stairsteps. 300 square feet of pool water surface area shall be reserved around each diving board or diving platform and this area shall not be included in computing the area of the swimming area. 3109.2 Definition. All outdoor inground swimming, wading or special purpose pools constructed after October 2, 1975 shall be enclosed by a fence six feet in height and firmly secured at ground level provided that any board or stockade fence and structure shall be at least five feet in height, but if over five feet in height, the fence shall be chain link.